Brand Name : UN-Medical
Model Number : UN-M7112
Certification : ISO
Place of Origin : China
MOQ : 1pc
Payment Terms : , T/T, D/A, D/P, Paypal,Western Union, MoneyGram, L/C
Supply Ability : 10000pcs one month
Delivery Time : 3-7 days
Packaging Details : carton
Lead System : 12 Leads
Parameters : ECG/TEMP/RR
Power supply : 5V
EMC standard : EN60601,EN60601-1-2,IEC601-1
Protocol : UN-Medical ECG
OEM : Support
Warranty : 1 year
Weight : <100g
OEM 3/5/12 Lead Temperature Respiration ECG Module for Patient Monitor
| Adopting digital filter technology | 
| Selectable 50Hz or 60Hz band stop filter | 
| 500Hz,7 /12 lead synchronous sample and analysis | 
| Character Classification Up to twelve sort, and 3-channel ST Segment Monitoring | 
| Anti high-frequency electric-knife | 
| Adopting single 5V power supply,low consumption and safely insulation | 
| 5V TTL Communication | 
| 2-channel temperature detect ,and two sort of sensor model | 
| Detecting respiration by impedance between RA-LL | 
|  			 8-channel ECG waveform  |  		
|  			 ST Segment Analysis  |  		
|  			 Heat rate calculation  |  		
|  			 Arrhythmia analysis  |  		
|  			 Lead off status indication  |  		
|  			 Lead mode  |  			 			 12 leads (R, L, F, N, C1~C6 or RA, LA, LL, RL, V1~V6 )  |  		
|  			 Selection  |  			 			 I, II, III, aVR, aVL, aVF, Vx, CAL  |  		
|  			 Gain  |  			 			 ´0.25V/mV, ´0.5V/mV, ´1V/mV, ´2V/mV  |  		
|  			 Heart rate(HR)  |  			 			 Range: Adult 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpm Accuracy: ±1% or ±1bpm Sensitivity: > 200 uVpp  |  		
|  			 Differential Input Impedance  |  			 			 > 5 MΩ  |  		
|  			 CMRR  |  			 			 > 100 dB  |  		
|  			 Electrode offset potential  |  			 			 ±400mV  |  		
|  			 Insulation Intensity  |  			 			 4000VACrms  |  		
|  			 Baseline Recovery  |  			 			 < 3 s, after Defi.  |  		
|  			 ECG Signal Range  |  			 			 >±5 mVpp  |  		
|  			 Bandwidth  |  			 			 Diagnostic 0.05 ~ 100 Hz Monitor 0.5 ~ 40 Hz Surgery 1 ~ 20 Hz Strong filter 5 ~ 20Hz  |  		
|  			 Calibration Signal  |  			 			 1mVpp,Accuracy ±3%  |  		
|  			 ST segment monitoring range  |  			 			 -2.0mV ~2.0mV  |  		
|  			 Arrhythmia analysis  |  			 			 ASY,VF/VTA,CPT,RUN,BGM,TGM,R on T(ROT),VPB,TAC,BRD,MIS,PNC,PNP  |  		
|  			 Waveform  |  			 			 1 ch  |  		
| Respiration Rate |  			 dult 7-120bpm   			Ped and Neo 7-150bpm   			Resolution 1bpm   			Accuracy ±2bpm  			 |  		
| Suffocation alarm | 10-40s Gain 10levels | 
| Baseline Impedance |  			 500 - 4000Ω  |  		
| Measuring Range |  			 0.5 - 5Ω  |  		
|  			 Channel Number  |  			 			 2 ch  |  		
|  			 Probe type  |  			 			 2K and 10K probe  |  		
|  			 Range  |  			 			 0-50°C  |  		
|  			 Resolution  |  			 			 0.1°C  |  		
|  			 Accuracy  |  			 			 ±0.1°C  |  		




| 
                                             | 
                